When there is a mixture of interfaces with and without redundancy, assign values in ascending order to the interfaces without
redundancy as well.
Interface entries with redundancy settings are only activated with Linux. With Windows, these interface entries will be
ignored.
Table 17.5 Interface Entry Settings (with Redundancy)
Setting Keyword Expected Values: Description
PRIMECLUSTER
GLS virtual
interface name
VIF_NAME sha
X X
is an integer between 0 and 255.
IP address specified
for virtual interface
VIF_IPAD
IP address in
xxx.xxx.xxx.xxx
format
-
Subnet mask VIF_MASK
Subnet mask in
xxx.xxx.xxx.xxx
format
-
Name of primary
interface
PRI_NAME
Interface name
(eth
X
)
X
is an integer equal to or greater than 0.
This setting specifies the primary interface
name when a pair of interface names exists.
<Example> eth2
Name of secondary
interface
SCD_NAME
Interface name
(eth
Y
)
Y
is an integer equal to or greater than 0.
This setting specifies the secondary
interface name when a pair of interface
names exists.
<Example> eth3
IP address of
monitored
destination
POL_ADDR
IP address in
xxx.xxx.xxx.xxx
format
Up to two IP addresses can be specified,
separated by a comma.
When hub-to-hub monitoring is to be
performed, specify two monitored
destinations.
Hub-to-hub monitoring will not be
performed if only one destination is
specified.
In this case, the value specified in
POL_HUBS (whether to perform hub-to-
hub monitoring) will not be referenced.
Virtual interface
name for standby
patrol
PAT_NAME sha
Y
Y
is an integer between 0 and 255.
Specify a name that is different from the
virtual interface name.
Do not set anything unless standby
patrolling is set.
Hub-to-hub
monitoring
ON/OFF
POL_HUBS ON/OFF
Specify "ON" to enable hub-to-hub
monitoring, or "OFF" otherwise.
This setting is valid only if two monitoring
destinations are specified.
If only one monitoring destination is
specified, this setting is disabled (set to
"OFF").
Refer to the PRIMECLUSTER Global Link Services manual for details on each setting.
- 139 -