a. In the [Failover Cluster Management] window, right-click the [Deployment Service] resource in [Summary of RC-manager]-
[Other Resources], and select [Properties] from the popup menu.
The [Deployment Service Properties] window is displayed.
b. In the [Registry Replication] tab, select the above registry key.
c. Click <Remove>.
The selected key is removed from the "Root registry key" list.
d. After removing the registry key, click <Apply>.
e. Click <OK> to close the dialog.
2. Change the location of the image file storage folder.
Change the location of the image file storage folder according to the instructions given in "5.8 rcxadm imagemgr" in the "Reference
Guide (Command) VE".
Because image files are actually copied over to the new location, this step may take some time to complete.
Run the rcxadm imagemgr command from either node of the cluster resource.
The new location should be a folder on the shared disk.
3. Restore registry replication settings.
Restore the registry key deleted in step 1 to the registry replication settings of the [Deployment Service] resource.
Use the following procedure to restore the registry key.
a. In the [Failover Cluster Management] window, right-click the [Deployment Service] resource in [Summary of RC-manager]-
[Other Resources], and select [Properties] from the popup menu.
The [Deployment Service Properties] window is displayed.
b. Click <Add> on the [Registry Replication] tab.
The [Registry Key] window will be displayed.
c. Configure the above registry key in [Root registry key].
d. Click <OK>.
e. After configuration of the registry keys is complete, click <Apply>.
f. Click <OK> to close the dialog.
[Linux Manager]
1. Mount the shared disk on the primary node.
Log in to the primary node with OS administrator privileges and mount the admin server's shared disk.
2. Change the location of the image file storage directory.
Change the location of the image file storage directory according to the instructions given in "5.8 rcxadm imagemgr" in the
"Reference Guide (Command) VE".
Because image files are actually copied over to the new location, this step may take some time to complete.
Run the rcxadm imagemgr command on the primary node.
Also, specify a directory on the shared disk for the new image file storage directory.
3. Un-mount the shared disk from the primary node.
Un-mount the shared disk (for which settings were performed in step 1) from the primary node.
8.6 Changing the Password for the Resource Orchestrator
Database
Use the following procedure to change the password for the Resource Orchestrator database:
- 64 -