SNMP Community
Enter the SNMP community that was set on this LAN switch.
Either select [public] or enter an arbitrary string.
Enter a string of up to 32 alphanumeric characters, underscores ("_"), and hyphens ("-").
3. Click <OK>.
The registered LAN switch will be displayed in the network device tree.
Note
It is possible to set an automatically detected IP address to another unregistered LAN switch. However, this will result in the Resource
Orchestrator configuration being inconsistent with the actual network configuration.
If a LAN switch was registered with the IP address of another network device, delete the registered LAN switch following the instructions
given in "11.4.2 Deleting LAN Switches ", then perform Discover and Register again.
7.4.3 HBA address rename Settings
Use the following procedure to configure HBA address rename settings.
The HBA address rename function allows the admin server to control the WWNs set on a managed server's HBAs. Since the admin server
carried over these settings when performing maintenance on or switching managed servers, it is not necessary to set the storage side
configuration again.
Use of the HBA address rename function requires registering specific settings for each managed server in advance.
Note
- The HBA address rename function is not available if ServerView Deployment Manager is used on the admin LAN. For details, refer
to "Appendix B Co-Existence with ServerView Deployment Manager" in the "Setup Guide VE".
- For servers which already have server switchover configured, when configuring or changing HBA address rename, the following
conditions must be met:
- Primary servers with HBA address rename configured
- Spare servers with the server switchover method HBA address rename configured
For any servers that do not meet these conditions, cancel any existing recovery settings before enabling the HBA address rename
function on a server.
- HBA address rename and VIOM cannot be used together within the same chassis.
- When using PRIMEQUEST, FC cards set with HBA address rename cannot use the PHP function.
Restarting of a server is required after replacing the FC card.
1. Storage Settings
Refer to "8.2Configuring the Storage Environment" in the "Design Guide VE"to configure the storage.
When altering the configuration of a storage device already used by active servers, ensure those servers are powered off before performing
any configuration changes.
2. Settings for the HBA address rename Function
1. On the ROR console server resource tree, right-click the target server (or the physical OS or VM host on the server), and select
[Modify]-[HBA Address Rename Settings] from the popup menu.
The [HBA Address Rename Settings] dialog is displayed.
- 40 -