POST Message Description
0195 The CMOS system options have not been set.
Action:
If you have just replaced the real-time clock on the
system board, start the Setup program to set the
correct date and time. If the problem recurs, have
the system serviced.
If you have not just removed or replaced the
real-time clock, have the system serviced.
0198 The CMOS checksum is invalid.
Action: Have the system serviced.
0289 A change in the memory configuration occurred. Installing
memory incorrectly, such as not installing memory modules
in matched sets, can cause this problem. It can also occur if a
memory module is defective.
Action: Ensure that the memory modules are installed
properly (see “Installing Memory-Module Kits” on
page 113). If the modules are properly installed, run
the test programs to determine the cause of the
problem and the action to take. If the test programs do
not find the problem, have the system serviced.
0295 Address Line Short Detected.
Action: Have the system serviced.
0297 The memory size has decreased.
Action:
If you have just removed memory from the server,
start the System Configuration Utility. Save the
new configuration information; then, restart the
server. If the problem recurs, have the server
serviced.
If you have not just removed memory, have the
server serviced.
0299 ECC Error Correction failed.
Action: Turn off the system and wait 30 seconds; then, turn it
back on. If event logging is enabled, POST logs this
event in nonvolatile flash memory. If the problem
recurs, have the system serviced.