2-2 magicolor 330 - Base Engine Service Manual
Fault Isolation Procedures
2
NO PAPER SENSOR TEST
1. Enter Diagnostics and test Tray 1 No Paper Sensor.
2. Slide Tray 1 out of the printer.
3. Manually actuate and deactuate Tray 1 No Paper Sensor.
Does the Diagnostics Status Window display "actuated" when
you manually actuate the sensor?
Go to step 3 Replace the
No Paper
Sensor
Assembly
(RRP 9.18)
·
Step number
·
Action with substeps, additional information, and a question.
·
Action to take if the answer to the question is YES
·
Action to take if the answer to the question is NO