Minolta 330 Printer User Manual


 
magicolor 330 - Base Engine Service Manual 3-55
Primary FIPS: Error Messages
3.50 - Error Message: Call for Service BTR2 Error
There is a problem with BTR2.
Logic control on the MCU PWB detected that the current value measured across BTR2 was not within specifications.
Step Actions and Questions Yes No
SUSPECT COMPONENTS
The following components are associated with this specific prob-
lem. One or more of these components may have failed partially
or completely. If you cannot isolate the problem using this FIP,
replace each component listed below, one at a time, until the prob-
lem disappears.
• Wiring and connectors linking the components
• Belt Cleaner Assembly (RRP 9.76)
1
Replace the HVPS (RRP 9.120)
Does the error message still appear?
Go to step 2 Problem
solved
2
Replace the MCU PWB (RRP 9.123)
Does the error message still appear?
Go to step 3 Problem
solved
3
Replace the 2nd BTR Assembly (RRP 9.75)
Does the error message still appear?
Go to step 4 Problem
solved
4
Replace the IBT Belt Assembly (RRP 9.78)
Does the error message still appear?
Go to suspect
components
Problem
solved