magicolor 330 - Base Engine Service Manual 12-19
Wiring Diagrams and Signal Information
BD8 MCU PWB↔Fuser Tray Assembly↔Environment Sensor
The following table shows the signal names for this BD:
Signal Name Description
OIL CAM SOLENOID ON (L) 24VDC Switches the Oil Cam Solenoid. Low=On. High=Off
CLEANER CAM SOLENOID ON (L) 24VDC Switches the Cleaner Cam Solenoid. Low=On. High=Off
EXCHANGE SOLENOID PUSH ON (L) 24VDC Switches the Exchange Solenoid so paper exits to Face Down
Tray.
EXCHANGE SOLENOID PULL ON (L) 24VDC Switches the Exchange Solenoid so paper exits to Face Up Tray.
FUSER CHUTE FAN ON (H) 24VDC Switches the Fuser Chute Fan. Low=Off. High=On
FUSER IN PAPER SENSED (L) 5VDC Signal from the Fuser Entrance Sensor. Low=Actuated. High=Not
actuated
ENVIRONMENT TEMP Analog signal from the Environment Sensor