magicolor 330 - Base Engine Service Manual 9-109
Removal and Replacement Procedures
RRP 9.52 XL Rail Assembly (PL6.1.40)
Removal
1. Remove the Xerographic Cartridge (RRP 9.48).
2. Remove the ROS Assembly (RRP 9.47).
3. Disconnect P/J 83 from the Waste Toner Sensor.
4. Disconnect P/J 89 from the Toner Box Sensor.
5. Free the wire harnesses from the wire clamps (Figure 1).
6. Disconnect P/J 86 from the Erase Lamp.
7. Remove the two screws securing the XL Rail Assembly to the front of the printer frame (Figure 2).
8. Remove the two screws securing the XL Rail Assembly to the rear of the printer frame
9. Lift the XL Rail Assembly up through the top of the printer frame.
Replacement
1. Move all of the wire harnesses out of the way.
2. Lower the XL Rail Assembly drop through the top of the printer frame.
3. Insert the three tabs that are located at the rear of the XL Rail Assembly into the three holes at the rear
of the printer frame.
4. Position the front lip of the XL Rail Assembly so it is on the outside front of the printer frame.
5. Line up the four screw holes in the XL Rail Assembly with the four screw holes in the printer frame.
6. Use four screws to secure the Assembly to the printer frame.
7. Reconnect P/J 86 to the Erase Lamp.
8. Reconnect P/J 89 to the Toner Box Sensor.
9. Reconnect P/J 83 to the Waste Toner Sensor.
10. Secure P/J 83 and P/J 86 under the wire clamps.
11. Reinstall the ROS Assembly (RRP 9.47).
12. Reinstall the Xerographic Cartridge (RRP 9.48).