magicolor 330 - Base Engine Service Manual 9-27
Removal and Replacement Procedures
RRP 9.11 End Guide (PL2.2.16)
Removal
1. Remove Tray 1 from the printer.
2. Position the Tray so the bottom faces up.
3. Remove the Sector Gear (RRP 9.12).
4. Raise the Bottom Plate.
5. Squeeze the End Guide handles and slide the End Guide to the end of the guide track and remove the
End Guide.
Replacement
1. Raise the Bottom Plate.
2. Insert the End Guide knob into the end of the guide track.
3. Squeeze the End Guide handles and slide the End Guide onto the track.
4. Position the Tray so the bottom faces up.
5. Reinstall the Sector Gear (RRP 9.12).
6. Squeeze the End Guide handles and slide the End Guide back and forth to make sure it moves
smoothly in the guide track and that the Sector Gear moves smoothly against the Tray Size Actuator.
7. Reinstall the Bottom Cover to the Tray.
8. Use five screws to secure the Bottom Cover to the Tray.
9. Reinstall Tray 1 into the printer.