CHAPTER 4 FUNCTIONS
4
4.1 Control Mode Selection Function
(2) Selectable control mode
A control mode can be selected from five modes.
Select the control mode on Switch Setting.
For details on the setting method, refer to the following.
Page 299, Section 6.2
Control for each channel is as follows.
*1 Only temperature measurement using a temperature input terminal can be performed. ( Page 262, Section 4.27)
*2 Heating-cooling control is performed using an output module in the system. ( Page 164, Section 4.1 (3))
Control mode Contents Number of controllable loops
Standard control Performs the standard control of four channels Standard control 4 loops
Heating-cooling control
(normal mode)
Performs the heating-cooling control. CH3 and CH4 cannot be used. Heating-cooling control 2 loops
Heating-cooling control
(expanded mode)
Performs the heating-cooling control. The number of loops is expanded
using an output module and others in the system.
Heating-cooling control 4 loops
Mix control
(normal mode)
Performs the standard control and the heating-cooling control. CH2 cannot
be used.
Standard control 2 loops
Heating-cooling control 1 loop
Mix control
(expanded mode)
Performs the standard control and the heating-cooling control. The number
of loops is expanded using an output module and others in the system.
Standard control 2 loops
Heating-cooling control 2 loops
Channel
Standard
control
Heating-cooling control Mix control
Normal mode Expanded mode Normal mode Expanded mode
CH1 Standard control
Heating-cooling
control
Heating-cooling
control
Heating-cooling
control
Heating-cooling control
CH2 Standard control
Heating-cooling
control
Heating-cooling
control
*1
Heating-cooling control
*2
CH3 Standard control
*1
Heating-cooling
control
*2
Standard control Standard control
CH4 Standard control
*1
Heating-cooling
control
*2
Standard control Standard control