C–Brocade CEE/FCoE Switch/Blade Configuration
Configure CEE Port
C-6 FE0254601-00 A
4. Verify the LLDP/DCBX configuration (Transmit TLVs) by issuing the
following command:
(config)# do show lldp
LLDP Global Information
system-name: swd77
system-description: Fibre Channel Switch.
description:
State: Enabled
Mode: Receive/Transmit
Advertise transmitted: 30 seconds
Hold time for advertise: 120 seconds
Re-init Delay Timer: 2 seconds
Tx Delay Timer: 1 seconds
Transmit TLVs: Chassis ID Port ID
TTL IEEE DCBx
DCBx FCoE App DCBx FCoE Logical Link
Link Prim Brocade Link
DCBx FCoE Priority Bits: 0x8
Configure CEE Port
To configure the CEE switch port to which the QLogic 8100 Series Adapter is
connected:
1. Enter the interface configuration mode for the CEE switch port that connects
to the QLogic adapter by issuing the following command. In the example, the
QLogic adapter port is connected to CEE port 0/19 on the Brocade switch.
(config)# interface tengigabitethernet 0/19
2. Enable the layer 2 switching mode by issuing the following command:
(conf-if-te-0/19)# switchport
3. Set the CEE port to converged mode by issuing the following command:
(conf-if-te-0/19)# switchport mode converged
4. Activate the VLAN classifier group 1 rule and assign VLAN 1002 to the CEE
port by issuing the following command:
(conf-if-te-0/19)# vlan classifier activate group 1 vlan 1002
5. Assign the CEE-MAP to the CEE switch port interface by issuing the
following command:
(conf-if-te-0/19)# cee demo
6. Enable the CEE port by issuing the following command:
(conf-if-te-0/19)# no shutdown