INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993
DDCB
DK16 KDCU,
CKTl
- OR-
DK16 PDKU,
CKTl
-OR-
DK16 DIGITAL
CKT5 OF
BASE UNIT
-OR-
DK8 KSU,
CKT 3 AND 4
DOOR PHONE
TO CUSTOMER
DOOR PHONE
B
DOOR PHONE
DDCB TO DK8 KSU WIRING CHART
DDCB TO DK16 BASE UNIT WIRING CHART
03
DT (32) / DR (7) ;; PIN 3 I4
PT (33) / PR (8) PIN 5 I6
NOTES
1. Relay control contact will close when the door phone is in the
ringing, talk, or monitor state.
2. See Paragraph 4.25 for Door Lock assignments.
3. Relay contact specifications are -24 VDC at 1 .O amp. max. Do
not connect relay contacts to 120 AC commercial power.
I
BASE UNIT
AMPHENOL
TO DDCB KSU JACK
I
TO PIN 3/4
PT (35) / PR (10) TO PIN 5/6
DDCB TO DK16 EXPANSION UNIT
WIRING CHART
See Figure 8-4 for DK16 Base Unit, PDKU, and
KCDU pin-out information
-.A..-- - -
FItiUHt 7-Y
DK8 AND DK16 DOOR LOCK CONTROL OPTION (DDCB)
5)
Access
Programs 29-1
- 29-2 to program a
Night Transfer button (NT1 or NT2) on all
DSS consoles that are to transfer the system
into the NIGHT mode.
7B) Solder the jumper W2 on the PIOUS to the
MAKE or BREAK position, as required:
l
MAKE-Shorts the normally open con-
tacts (NHT and NHR) when the night
relay is activated.
6) If tenant operation is required, access
Program
l
BREAK-Opens the normally closed
15
to set the CO lines for tenant 1 (NM) or
contacts (NHT and NHR) when night
tenant 2 (NTZ) operation. relay is activated.
7A) Set the
PI1
jumper plug on the PIOU to the
MAKE or BREAK position, as required:
l
MAKE-Shorts the normally open con-
tacts (pins 9 and 34) when the night relay
is activated.
8) Refer to Figures 7-6 and 7-7 for wiring/inter-
connecting details. Connect the PIOU or PI-
OUS to the MDF as required for the night relay
function.
NOTE:
l
BREAK-Opens the normally closed
contacts (pins 9 and 34) when the night
relay is activated.
Door phones programmed to ring over exter-
nalpage in night mode (Program 77-l) do not
activate the NT relay.
7-11