Toshiba DK16 Network Card User Manual


 
INSTALLATION-DK16 KSU & PCB
SECTION lOO-816205
MARCH1993
llllllllllll
111111111111111 YTT
MOUNTING HOLE
KPSU16A
POWER SUPPLY
AC POWER CABLE
I
FG SCREW
(LEFT SIDE)
DC CABLE
llllllllllllllllll1lllllllll
I
-24V CIRCUIT
BREAKER
(RIGHT SIDE)
TERMINAL THAT IS
FASTENED TO
POWER SUPPLY
FG SCREW
FGI GREEN/YELLOW WIRE RUN
UNDERNEATH POWER SUPPLY
BEHIND STAND-OFFS
DC OUT (P9) CONNECTOR
(KPSUI 6 VOLTAGE TEST POINTS)
GREEN/YELLOW WIRE
(RIGHT-HAND SIDE)
FIGURE 5-10
POWER SUPPLY (KPSU16)
4) Plug the DC cable into the DC OUT connector.
7) Plug the AC power cable into an outlet and
Green/yellow wire is on right-hand side (Figure
turn ON the power supply switch.
5-10).
8) Refer to Paragraph 2.10 to confirm that the
5) Fasten FG green/yellow wire ring terminal and
power supply is working properly.
building ground wire to the left side of the
power supply with the FG screw.
9) Plug reserve battery cable into BAlT connec-
tor of power supply (Figure 5-10).
6) Re-install K4RCU PCB (if required).
5-12