Drum Unit Replacement
Replacement Drum Kits include
an Ozone Filter and Drum unit.
Be sure to replace the Ozone
Filter when replacing the Drum
Unit.
Your TOSHIBA facsimile has
been designed to display a two-
stage alert to replace the Drum
Unit once it has been depleted.
The first stage is a “DRUM UNIT
WARNING” that alerts you that
the Drum Unit is at or near its
end of life and should be re-
placed at your earliest convince.
The unit will continue to receive
and print facsimile messages
during this stage.
The second stage is “REPLACE
DRUM UNIT.” When this mes-
sage is displayed, the machine
can no longer print documents.
Receptions will be stored in
memory until the Drum Unit has
been replaced.
For the purpose of determining
Drum usage;
Each legal-size sheet of paper
counts as 1.3 letter-size sheets
of paper.
Remove the Developer Assem-
bly with the Drum Unit attached.
IMPORTANT:
Never touch the photo-
conductive drum (the
green surface) of the
Drum Unit. If the surface
is scarred or scratched, it
will cause print quality
problems.
Do not expose the photo-
conductive drum of the
Drum Unit to light for
more than 3 minutes. If
the Drum Unit is to be left
anywhere outside the fac-
simile, be certain to cover
it with cloth, paper, etc.
Separate the Drum Unit from the
Developer Assembly.
STORAGE NOTES:
The Drum Unit is a very im-
portant part of this facsimile.
Handle it with care as shown
below.
Keep the Drum Unit within a
temperature range of 0-35°C
(32-95°F) and a humidity
range of 20-80%RH (without
condensation).
Do not store or use the Drum
Unit in an environment
where the temperature
changes excessively.
Do not touch the light sensi-
tive drum because its sur-
face will be easily damaged.
Do not place the light sensi-
tive drum in a location where
it is exposed to direct sun-
light or high intensity light
(more than 200 lx) such as
near a window.
Grasp the Top Cover Release
Lever and open the Top Cover.
Open the Top Cover
1
Separate the Drum
Unit
3
Remove the
Developer Assembly
with Drum Unit
2
Top Cover
Release Lever
037
Developer
Assembly
051
Drum Unit
Developer
Assembly
052