rule will be an assembly error code between xx00 - xx09, where xx is
the assembly that is suspected of failing during normal operation. For
example, error 0500 is a run-time error related to the A5 A/D assem
-
bly.
4000 - 4999 These messages indicate internal H/W calibration problems.
5000 - 5999 These messages indicate run-time RF power problems.
6000 - 6999 These messages indicate run-time phase lock problems. A letter or se
-
quence of letters following the error message depict the suspect assem
-
bly(ies) as follows:
q
A = 10 MHz Reference
q
B = LO1 unlocked
q
C = LO2 unlocked
q
D = Source unlocked
q
E = IF lock signal level too low
q
F = External synthesizer unlocked
q
G = LO3 unlocked
q
None = Unknown
7000 - 7999 These messages indicate a run-time digital section problem.
8000 - 8999 These messages indicate a run-time processing system problem.
SERVICE LOG ERROR MESSAGES APPENDIX B
B-4 373XXA MM