3 Installing a New G700 with an S8300: Administer Communication Manager
154
Installation and Upgrades for G700 with S8300 or S8700
555-234-100 — Issue 3 — May 2003
4. Complete the Network Region field with the value supplied in the planning documentation.
5. If specifically requested by the customer or your planning documents, type gateway-
announcements
in the V9 field. This field allows you to enable announcements on the G700
Media Gateway. V9 is a virtual slot. There is no announcement board associated with it. The
announcements for the G700 are available in the G700 firmware and are administered in the same
way as announcements on the TN2301 circuit pack used on S8700 port networks.
If there are multiple G700 Media Gateways sharing announcements, then enable announcements
on the G700 whose trunks will receive the announcements most often.
6. Press F3 (ENTER) to save your changes.
If properly administered, the G700 should register with the primary controller within 1–2
minutes. The IP Address, MAC Address, and Module Type fields are populated automatically
after the G700 Media Gateway registers with the server.
7. Type change media-gateway to view the Media Gateway form.
Media Gateway Screen (After Registration with Primary Controller)
The media modules installed in the G700 are listed next to their slot numbers.
To verify that a G700 Media Gateway has been successfully added:
Verify Changes
1.
At the SAT prompt, type list media-gateway.
change media-gateway 1 Page 1 of 1
MEDIA GATEWAY
Number: 1
Name: Swainsons Identifier: 012X06230551
IP Address: 145. 9. 73.101 MAC Address: 00:04:0d:02:05;0a
Network Region: 1 Location: 1
Site Data: Registered? y
Slot Module Type
V1: icc
V2: ds1
V3: analog
V4: dcp
V8: messaging-analog
V9: