Galaxy Metal Gear 65 Computer Accessories User Manual


 
Galaxy 65 User Guide
86
7.19.3 Voltage and Temperature Errors and Warnings
Most voltage and temperature errors and warnings relate to the Power Supply/Cooling modules. Check
the following to resolve these errors or warnings:
1 Check that all of the fans are working by making sure all of the Galaxy 65 Subsystem’s LEDs are green
or using the SAM status pages.
2 Make sure that all the Galaxy 65 Subsystem modules are properly seated in their slots and that their
handles are locked.
3 Make sure that no slots are left open for more than two minutes.
If you need to replace a module, leave the old module in place until you have the replacement or use a
blank cover to close the slot. Leaving a slot open negatively affects the airflow and may cause the unit to
overheat.
4 Try replacing each Power Supply/Cooling module, one at a time.
5
Replace the SM modules, one at a time.
7.20 Slow Write Performance
This can be caused by powering down the enclosure without first shutting down the controllers.
The battery must be greater than 90% charged for write back cache to be enabled.
PrtcolError Galaxy 65 Subsystem detected an unrecoverable protocol error on the part of the
target.
QueueFull Target reported queue full status.
Stat: 04 Data overrun or underrun occurred while getting sense data.
Stat: 05 Request for sense data failed.
Stat: 32 Target has been reserved by another initiator.
Stat: 42 I/O request was aborted because of Galaxy 65 Subsystem’s decision to reset the
channel.
Stat: 44 Galaxy 65 Subsystem decided to abort I/O request for reasons other than bus or target
reset.
Stat: 45 I/O request was aborted because of target reset requested by Galaxy 65 Subsystem.
Stat: 46 Target did not respond properly to abort sequence.
Table 7–8 Disk channel error codes (Continued)
Error Code Description