Galaxy 65 User Guide
200
Table 7–2 Ops Panel Switch Functions
•
Initiator ID assigned to each channel
: The Galaxy 65 Subsystem assigns each of its FC disk
channels one of the FC loop IDs (initiator IDs). The Initiator ID setting is set via the Disk Array
Administrator. You can change the initiator ID assigned to each channel. You may need to do this if
the default ID, 125, conflicts with an EMP ID. You have two options:
– SOFT: Use this setting if you do not care whether the channel’s initiator ID changes when you
power down and power up. This setting lets the FC loop initialization process determine the
initiator ID.
– Any number between 0 and 125: Select a specific number if you want the initiator ID to stay the
same after you power down and power up. The Disk Array Administrator software cannot tell you
which IDs are available. To be sure that you have successfully assigned the ID you want, check
the ID after you restart the Galaxy 65 Subsystem. If the Galaxy 65 Subsystem cannot get the
specified Loop ID during the loop initialization process, it will try to get a soft address.
To configure the FC disk channels:
1 From the System Menu, select Configuration Menu and press Enter.
The Configuration Menu displays.
2 Select Channel Configuration and press Enter.
The Select Disk Channel screen displays.
Switch
Number
Function Recommended
Setting
Definition
1 Loop Select,
Dual (2x8) Off
LRC operates on two loops of 8 drives
Mandatory
2 Not Used Note: on Expansion enclosures this must be set On.
3 Not Used
4 Not Used
5 & 6 Not Used
7 & 8 Drive Loop Speed
Select
Sw7 Sw8
On Off Force 2Gb/s
Off Off Force 1Gb/s
9 & 10 Drive Addressing Mode
Selection
Sw9 Sw10
On Off Mode 2
11 SOFT SELECT On Select Functions using the hardware
switches
12 Not Used