Galaxy Metal Gear 65 Computer Accessories User Manual


 
Galaxy 65 Troubleshooting
87
7.21 Spare Parts and Ancillary Items
The following replaceable parts are available for the Galaxy 65 Subsystem:
7.22 Upgrading Your LRC I/O Modules
You can upgrade your existing JBOD or RAID LRC module to a Rorke Data Galaxy 65 RAID LRC module
in accordance with the following procedure:
Caution Ensure that your Power Supply/Cooling modules are marked with P/N 44191-XX. If they are not you will
need to upgrade your PSUs. Please contact your supplier and request the upgrade modules.
1
Change the Ops Panel switch settings to those shown in Table 7–9.
Important Switch settings are only read at Power On.
The Galaxy 65 enclosure ID must always be set to select ID1.
2 Remove the existing LRC modules in accordance with the procedure in 7.12.3.1, ”Removing the Module”,
on page 72.
3 Install the Storage Manager modules in accordance with the procedure in 7.12.3.2, ”Inserting the
Module”, on page 73.
Chassis (including Backplane) RS232 cable
AC Power Supply/Cooling Module LAN cable
Drive Carrier Module 19 inch rack mounting rail kit
Storage Manager Module Dummy Carrier Module
External FC-AL Signal Cables Blank SM Module
Cables SFP module, optical
LC - LC optical cable SFP module, copper
LC - SC optical cable Battery, Li-ion
SFP - SFP copper patch cable (1 M length) (Country specific) power cords
HSSDC2 - HSSDC1 Bifurcated power cords
HSSDC2 - DB9 Keys for Drive Carrier modules.
HSSDC2 - HSSDC2 All documentation