Managing Drives & Enclosures
175
To display all drives:
1
From the System Menu, select
Display Drives
and press
Enter
.
The Display Drives screen displays.
If a drive has an E in the first column, select the drive and press Enter to display the error.
To reset the error statistics, select Reset drive error statistics and press Enter.
To blink the selected drive, press B. The blink function is a toggle. Press B again to stop the blinking. You
can also blink more than one drive by selecting each drive and pressing B.
To toggle the display between the drive model number, serial number, and the node and WWN, press T.
2 Press Esc to return to the System Menu.
F.1.1.2 Viewing Drive Status
You can view the status of the drives in an array, including the following information:
• Drive number: The drive’s sequential position in the Galaxy 65 Subsystem’s drive list
• Drive status: Whether the drive is up or down
• Spare: Displays SPR if the drive is a dedicated spare for the current array
• Channel number: Back-end disk bus number
• Channel and Loop ID: ID for the I/O modules the drive is connected to and the loop ID for the FC
disk port