Galaxy 65 User Guide
14
1.6.9 Galaxy 65 FC-AL LRC I/O Module Specification
1.6.10 RAID Card
1.6.11 Software Enclosure Services (SES) Support
The enclosure has a sophisticated self-monitoring and reporting function which conforms to ANSI SES
specifications.This reports on such topics as:
–
Enclosure temperature
– Fan speed
–
Drive condition
–
Operator panel status
– RAID controller status: Not Ready, Partner Fail and Partner Present outputs
For more information on the implementation of this function please request a copy of the SES
specification from your supplier.
LRC-Galaxy 65 Speed 2Gb
• Creates connections to 2 x 8 drive mode dual loop structures
• 2 external Expansion ports, SFP connectors
• 2 Host SFP ports
• 1 Ethernet port
Mounting Rear, single bays 3 and/or 4 (see Figure 1–3)
Connectors
• 2 x SFP module LC optical, max. cable length 500m, or,
• 2 x Copper HSSDC-2 connector, max. cable length 6m.
• 1 x RJ42 Ethernet connector
• 1 x RS232, 6 pin Mini-DIN (factory use only)
Battery Backup Li-ion Battery, Hold up time for RAID cache:
–
512Mb: 72 hours (worse case)
LED Functions
• Host Port 0 Signal Good Green
• Host Port 1 Signal Good Green
• Expansion Port 0 Rx Good Green
• Expansion Port 1 Rx Good Green
• ESI/LRC module fault LED Amber
• Cache Active Green
• RAID Controller Ready Green
• Battery Fault Amber
Power Dissipation
5A @ 3.3V
7.4A @ 5V
RAID Integrated Fibre - Fibre controller
600k Hrs MTBF
LRC & ESI Function 1.2 MHz
Memory 512Mb - 1Gb