7.15.1 Warnings
Warning events let you know that something related to the Galaxy 65 Subsystem or an array has a
problem. You should correct the problem as soon as possible. Table 7–4 defines each warning event and
recommends the action you should take.
Table 7–4
Warning events
Event Definition Recommended Action
ARRAY CRITICAL One or more drives are down and the
array is online, but is no longer fault
tolerant.
Add a spare to the array or the spare
pool. Then replace the bad drives.
Refer to the Galaxy 65 Subsystem
Getting Started Guide.
ARRAY OFFLINE More than one drive in a RAID 0 or
volume set went down bringing the
array to an offline state. This array is
no longer accessible by the host.
Replace the bad drive and restore the
data from backup.
BATT FAIL INFO A warning condition in the battery pack
or charging interface has been
detected.
Replace the battery, see section
7.12.5 on page 74.
BOOT ONLINE
FAIL
During startup, the system attempted
to put the specified module online.
This operation failed.
The event gives a reason why the Put
Online failed. Examine this reason and
take the appropriate action. If the
reason is DIAGNOSTIC FAIL, a
hardware problem was found with the
module. In this case, try replacing the
module with a different one.
DISK CHAN
DEGRAD
Errors detected on one of the disk
channels have caused the Galaxy 65
Subsystem to mark the channel as
degraded.
Determine the source of the errors on
the specified disk channel and replace
the faulty hardware.
DRIVE DOWN An error occurred with the drive and it
was downed, removing it from the
active array.
Add a spare to the array or the spare
pool. Then replace the bad drive. Refer
to the Galaxy 65 Subsystem Getting
Started Guide.
HW STATUS
CHANGE
A SM has detected a significant
change in the status of one of the
power modules.
If the event indicates that the module
has failed or is not present, install a
new module.