Q-Logic 64 Switch User Manual


 
A – Command Line Interface
Show Command
A-64 59048-04 Rev. B
D
5 CPU-0 * Good Passed Normal *
6 IO-4 32-39 Good Compromised Normal 0
7 IO-5 40-47 Good Passed Normal 0
8 IO-6 - NotInstalled NotInstalled Normal 0
9 IO-7 - NotInstalled NotInstalled Normal 0
10 PS-1 * NotInstalled Passed Normal *
11 CC-0 * Good Passed Normal *
12 CC-1 * Good Passed Normal *
The following is an example of the Show Switch command:
SANbox2 #> show switch
Switch Information
------------------
SymbolicName sw .108
SwitchWWN 100000c0dd00bc56
SwitchType SANbox2-64
BootVersion V1.0.0.7-0 (Mon Nov 3 13:11:08 2003)
CreditPool 0
DomainID 19 (0x13)
FirstPortAddress 130000
FlashSize - MBytes 128
LogLevel Critical
MaxPorts 64
NumberOfResets 224
ReasonForLastReset PowerUp
SWImageVersion (1) - build date V4.0.0.0-17 (day month date time year)
SWImageVersion (2) - build date V4.0.0.0-17 (day month date time year)
ActiveImageVersion - build date V4.0.0.0-2 (day month date time year)
PendingImageVersion - build date V4.0.0.0-17 (day month date time year)
ActiveConfiguration default
AdminState Online
AdminModeActive False
BeaconOnStatus False
OperationalState Online
PrincipalSwitchRole False
SwitchDiagnosticsStatus Passed
The following is an example of the Show Topology command:
SANbox2 #> show topology
Unique ID Key
-------------
A = ALPA, D = Domain ID, P = Port ID
Port Local Local Remote Remote Unique