Q-Logic 64 Switch User Manual


 
C – Messages
Zoning Dialog
59048-04 Rev. B C-19
D
The zone set you attempting to activate
contains port based zoning and there are
switches in the fabric that might not
support this type of zoning. Some E_Ports
may isolate. Do you wish to continue?
Not all switch vendors support port-based
zoning. Consult the manual for these
vendors’ switches to determine whether to
apply this zoning configuration to the
fabric.
The zoning configuration has been
changed. Would you like to apply your
changes?
The zoning configuration includes
changes that have not been applied to the
switch. Select Yes to apply the changes to
the switch before continuing, or select No
to discard the changes and continue.
There is already a zone by that name in a
different Zone set. Would you like to add
that zone to this Zone Set?
If the existing zone is the same as zone
that the user wants to add to this zoneset,
then continue. Otherwise, select a unique
name for the new zone and retry the
operation.
There is already a zone set with that
name.
Or
There is already a zone with that name.
Or
There is already a alias with that name.
Select a unique name for the new object
and retry the operation.
This zoning configuration exceeds the
limits for this switch.
Remove unnecessary objects from the
zoning configuration and retry the
operation.
Unable to create alias. The zoning configuration already contains
the maximum allowed zoning aliases.
Delete any unwanted aliases and retry the
operation.
You are about to save a zoning
configuration that was not completely read
in. Saving this version will make the
incomplete database permanent.
An error was encountered while reading
the zoning database from the switch, and
so the database edited by the user may be
missing some zoning information.
You have zones in the orphan zone set.
These are not saved in the switch. Would
you like to continue?
Orphan zones are not applied to the
switch. If the orphan zones are to be
applied to the switch, they must first be
added to a configured zoneset. Orphan set
is not saved on switches, and is used only
in the application while configuring zoning
information.
Table C-11. Zoning Dialog Messages (Continued)
Message User Action