C – Messages
Port Properties Dialog
59048-04 Rev. B C-9
D
Unable to apply changes. Failed to obtain
admin privileges.
Verify that another user is not currently
modifying the switch configuration, using
either the management application, or a
Telnet login, or any other application, and
then retry the operation.
Unable to confirm that port changes were
successful.
The application did not receive a required
response from the switch. This may be
caused by a momentary or extended loss
of communications with the fabric.
First refresh the information in the display
to determine whether the changes took
effect. If not, retry the changes.
If the error persists, determine whether
communications with the switch have
stopped, and resolve any network
problems. When communication with the
fabric has resumed, return to the
application to view the properties for the
port and verify whether the changes took
effect. If not, then retry the changes.
Unable to successfully apply port speed
change.
Or
Unable to successfully apply port state
change.
Or
Unable to successfully apply port type
change.
Verify that the data is valid, that the user
has permissions to modify the
configuration on the switch, that the switch
is reachable in the fabric, and that the
fabric is reachable from the user’s
workstation, then retry the configuration
change.
Table C-5. Port Properties Dialog Messages (Continued)
Message User Action