Q-Logic 64 Switch User Manual


 
3 – Managing Fabrics
Zoning a Fabric
3-18 59048-04 Rev. B
D
To restore the default zoning for a switch:
1. In the faceplate display, open the Zoning menu and select Restore Default
Zoning.
2. Click the OK button to confirm that you want to restore default zoning and
save changes to the zoning database.
3.4.4
Merging Fabrics and Zoning
If you join two fabrics with an inter-switch link, the active zone sets from the two
fabrics attempt to merge automatically. The fabrics may consist of a single switch
or many switches already connected together. The switches in the two fabrics
attempt to create a new active zone set containing the union of each fabric's
active zone set. The propagation of zoning information only affects the active zone
set, not the configured zone sets, unless FC-SW-2 Auto Save is turned on.
3.4.4.1
Zone Merge Failure
If a zone merge is unsuccessful, the inter-switch links between the fabrics will
isolate due to a zone merge failure, which will generate an alarm. The reason for
the E_Port isolation can also be determined by viewing the port information. Refer
to ”Port Information Data Window” on page 6-7 and the ”Show Command” on
page A-53 (Port keyword).
A zone merge will fail if the two active zone sets have member zones with
identical names that differ in membership or type. For example, consider Fabric A
and Fabric B each with a soft zone named “ZN1” in its active zone set. Fabric A
"ZN1" contains a member specified by Domain ID 1 and Port 1; Fabric B “ZN1”
contains a member specified by Domain ID 1 and Port 2. In this case, the merge
will fail because the two zones have the same name, but different membership.
3.4.4.2
Zone Merge Failure Recovery
When a zone merge failure occurs, the conflict that caused the failure must be
resolved. You can correct a failure due to a zone conflict by deactivating one of
the active zone sets or by editing the conflicting zones so that their membership is
the same. You can deactivate the active zone set on one fabric if the active zone
set on the other fabric accurately defines your zoning needs. If not, you must edit
the zone memberships, and reactivate the zone sets. After correcting the zone
membership, reset the isolated ports to allow the fabrics to join.
CAUTION!
This command will deactivate the active zone set.