Q-Logic 64 Switch User Manual


 
4 – Managing Switches
Configuring Port Threshold Alarms
4-16 59048-04 Rev. B
D
4.3
Configuring Port Threshold Alarms
You can configure the switch to generate alarms for selected events. Configuring
an alarm involves choosing an event type, rising and falling triggers, a sample
window, and finally enabling or disabling the alarm. To configure port threshold
alarms, do the following:
1. In the faceplate display, open the Switch menu and select Port Threshold
Alarm Configuration. The Port Threshold Alarm Configuration dialog
shown in Figure 4-9 prompts you to enable or disable all alarms, select an
event, set triggers, set a sample window and enable or disable an individual
alarm.
Figure 4-9. Port Threshold Alarm Configuration Dialog
2. Check the Enable All Port Threshold Alarms check box to enable
monitoring for all the individual alarm types that are enabled. The Enable All
Port Threshold Alarms check box is the master control for the individual
alarms. For example, the switch will monitor CRC errors only if both the
CRC Error Enable box and the Enable All Port Threshold Alarms box are
checked.
3. Select an event type from the Port Threshold Alarm pull-down menu.
Choose from the following options:
CRC error monitoring
Decode error monitoring
ISL monitoring
Login monitoring
Logout monitoring
Loss of signal monitoring
4. Check the Enable box to make the alarm eligible for use.