Q-Logic 64 Switch User Manual


 
4 – Managing Switches
Displaying Switch Information
4-12 59048-04 Rev. B
D
Legacy Address Format Legacy port addressing status. Enabled only for
interoperability with non-FC-SW-2 switches.
FC-SW-2 Auto Save Zoning auto save status. Saves zoning updates in
temporary memory and the zoning database (True) or
only in temporary memory (False).
Zoning Default Visibility Zoning visibility status. Permits (All) or prevents (None)
communication between attached devices in the absence
of an active zone set.
Temperature Internal switch temperature °C
Security Auto Save N/A
Security Fabric Binding
Enable
N/A
Fan 1 Status Fan 1 status
Fan 2 Status Fan 2 status
Fan 3 Status Fan 3 status
Power Supply 1 Status Power supply 1 status
Power Supply 2 Status Power supply 2 status
Beacon Status Beacon status. Switch LEDs are blinking (On) or not (off).
Broadcast Support Broadcast support status. Broadcast support is enabled or
disabled (default).
In-band Enabled In-band management status. Permits (True) or prevents
(False) a switch from being managed over an ISL.
Temp Failure Port
Shutdown
N/A
Warning Temperature N/A
Failure Temperature N/A
FDMI Enable Fabric Device Management Interface status. If enabled,
device information can be obtained, managed, and saved
through the fabric using Name Service Management
Server functions. SANbox Manager will report any and all
FDMI information reported by the entry switch, if FDMI is
enabled on the entry switch.
Table 4-4. Switch Data Window Entries (Continued)
Entry Description