Sun Microsystems 60 Computer Hardware User Manual


 
Chapter 10 Motherboard and Component Replacement 10-13
Caution – Each DIMM bank must contain at least four DIMMs of equal density (for
example: four 32-Mbyte DIMMs) to function properly. Do not mix DIMM densities
in any bank.
Note The system unit must have at least four identical DIMMs installed in any
DIMM bank. TABLE 10-1 identifies DIMM installation locations.
10.5.1 Removing a DIMM
Caution Handle DIMMs only by the edges. Do not touch the DIMM components
or metal parts. Always wear a grounding strap when handling a DIMM.
1. Power off the system unit.
See Section 6.2, “Powering Off the System Unit” on page 6-3.
2. Remove the side access cover.
See Section 7.1, “Removing the Side Access Cover” on page 7-2.
Caution – Use proper ESD grounding techniques when handling components. Wear
an antistatic wrist strap and use an ESD-protected mat. Store ESD-sensitive
components in antistatic bags before placing them on any surface.
3. Attach the wrist strap.
See Section 7.2, “Attaching the Wrist Strap” on page 7-3.
TABLE 10-1 DIMM Bank and Bank Quad
Bank Bank Quad
0 U0701, U0702, U0703, and U0704
1 U0801, U0802, U0803, and U0804
2 U0901, U0902, U0903, and U0904
3 U1001, U1002, U1003, and U1004