Sun Microsystems 60 Computer Hardware User Manual


 
4-10 Sun Ultra 60 Service Manual August 2001
4.6.3 probe-scsi and probe-scsi-all
probe-scsi transmits an inquiry command to internal and external SCSI devices
connected to the system unit on-board SCSI interface. If the SCSI device is connected
and active, the target address, unit number, device type, and manufacturer name is
displayed. probe-scsi-all transmits an inquiry command to SCSI devices
connected to the system SCSI host adapters. The first identifier listed in the display
is the SCSI host adapter address in the system device tree followed by the SCSI
device identification data.
CODE EXAMPLE 4-4 identifies the probe-scsi output message and CODE EXAMPLE 4-5
the probe-scsi-all output message.
CODE EXAMPLE 4-3 watch-net-all Output Message
{0} ok watch-net-all
/pci@1f,4000/network@1,1
Hme register test --- succeeded.
Internal loopback test -- succeeded.
Transceiver check -- Using Onboard Transceiver - Link Up.
passed
Using Onboard Transceiver - Link Up.
Looking for Ethernet Packets.
‘.’ is a Good Packet. ‘X’ is a Bad Packet.
Type any key to stop.
...
CODE EXAMPLE 4-4 probe-scsi Output Message
ok probe-scsi
Target 0
Unit 0 Disk QUANTUM VK4550J SUN4.2G8600
Target 6
Unit 0 Removable Read Only device TOSHIBA
XM5701TASUN12XCD0997
CODE EXAMPLE 4-5 probe-scsi-all Output Message
{0} ok probe-scsi
Target 0
Unit 0 Disk QUANTUM VK4550J SUN4.2G8600