4-4 Sun Ultra 60 Service Manual • August 2001
Symptom
A hard drive read, write, or parity error is reported by the operating system or
customer application.
A CD-ROM drive read error or parity error is reported by the operating system or
customer application.
Action
Replace the drive indicated by the failure message. The operating system identifies
the internal drives as listed in
TABLE 4-1.
Note – The # symbol in the operating system address examples may be a numeral
between 0 and 7 that describes the slice or partition on the drive.
Symptom
Hard drive or CD-ROM drive fails to respond to commands.
Note – To bypass POST, type: setenv diag-switch? false at the ok prompt.
Action
Test the drive response to the probe-scsi command as follows:
1. At the system ok prompt:
a. Type reset-all.
b. Type probe-scsi.
TABLE 4-1 Internal Drives Identification
Operating System Address Drive Physical Location and Target
c0t0d0s# Lower hard drive, target 0
c0t1d0s# Upper hard drive, target 1
c0t6d0s# CD-ROM drive, target 6 (optional)
c0t5d0s# Tape drive, target 5 (optional)