Sun Microsystems 60 Computer Hardware User Manual


 
Chapter 4 Troubleshooting Procedures 4-19
CODE EXAMPLE 4-15 identifies the parallel port output message.
4.7.8 Serial Port A
The serial port A diagnostic invokes the uart_loopback test. The
uart_loopback test transmits and receives 128 characters and checks the
transaction validity. The following baud rates are tested in asynchronous mode:
460800, 307200, 230400, 153600, 76800, 57600, 38400, 19200, 9600, 4800, 2400, and 800.
CODE EXAMPLE 4-16 identifies the serial port A output message.
CODE EXAMPLE 4-15 Parallel Port Output Message
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===> 6
TEST=’parallel_port_test’
SUBTEST=’dma_read’
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===>
CODE EXAMPLE 4-16 Serial Port A Output Message
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===> 7
TEST=’uarta_test’
BAUDRATE=’1200’
SUBTEST=’internal_loopback’
BAUDRATE=’1800’
SUBTEST=’internal_loopback’
BAUDRATE=’2400’
SUBTEST=’internal_loopback’
BAUDRATE=’4800’
SUBTEST=’internal_loopback’
BAUDRATE=’9600’
SUBTEST=’internal_loopback’
BAUDRATE=’19200’
SUBTEST=’internal_loopback’
BAUDRATE=’38400’
SUBTEST=’internal_loopback’
BAUDRATE=’57600’
SUBTEST=’internal_loopback’
BAUDRATE=’76800’
SUBTEST=’internal_loopback’
BAUDRATE=’115200’
SUBTEST=’internal_loopback’
BAUDRATE=’153600’