3-4 Sun Ultra 60 Service Manual August 2001
4. In a shell window on the Sun workstation, type tip hardwire.
Note The shell window is now a tip window directed to the serial port of the
system unit being tested. When power is applied to the system unit being tested,
POST messages will be displayed in this window.
5. When POST is completed, disconnect the tip window as follows:
a. Open a shell window.
b. Type ps -a to view the active tip line and process ID (PID) number.
c. Type the following to kill the tip hardwire process.
3.2.2 Verifying the Baud Rate
To verify the baud rate between the system unit being tested and a terminal or
another Sun workstation monitor:
1. Open a Shell window.
2. Type eeprom.
3. Verify the following serial port default settings as follows:
Note Ensure that the settings are consistent with TTY-type terminal or
workstation monitor settings.
hostname% tip hardwire
connected
% kill -9 PID#
ttyb-mode = 9600,8,n,1
ttya-mode = 9600,8,n,1