8. Lamp relay
→ When you select 1H/24H or 2H/1W , the box to set the lam p relay interval is displayed.
→ When the pr ojector is turned off, the setting is cleared and the projector resumes operation from the time of the power-on or
menu setting shown in the preceding step.
1H/24H
23H
0
OK
CLEAR
DEL
CANCEL
123456 78 9
← →
NEXT LAMP RELAY
Image 8-6
2H/1W
0
OK
CLEAR
DEL
CANCEL
123456 78 9
← →
6D 22H
NEXT LAMP RELAY
Image 8-7
9. Move the key cursor using t he direction keys to select the number you want to enter and then press the ENTER key.
→ Maximum interval
1H/24H
23H (23 hours)
2H/1W
6D 22H (6 days and 22 hours)
← key Shifting the position of enter cur sor to the left for each character.
→ key Shifting the position of enter cursor to the r ight for each c haracter.
DEL key Deleting the cha racter in the position of enter cursor for each character.
CLEAR key Deleting all the entered characters.
→ When the value you entered meets the following conditions, an error dialog box is displayed at the screen c enter.
- T he value has been cleared by DE L or CLEAR and left blank.
- T he value you entered is out of the setting ran ge.
1H/24H
24H or over
2H/1W
6D 23H or over
→ The value of each item is out of the setting range.
D
7orover(2H/1W
only)
H24orover
10.Whe n selecting OK, the s etting is completed as the lamp-switching interval stored. However, when selecting CANCEL,thesetting
is completed without storing.
→ The display returns the LAMP RELAY men u after selecting OK or CANCEL.
→ The setting you made is applied to NEXT LAM P RELAY in the INFORMATION menu.
Important
• When you use the projector continuously, the lamp relay may not be performed on time due to errors of the clock function.
• Immediately after the power-on, during the lamp selection, or during the lamp r elay operation, y ou cannot change the setting
of LAMP SELECT and LAMP RELAY.
• In the cas e of continuous projection, the lamps may deteriorate earlier unless they are turned off for 1 hour per week.
• When using this projector c ontinuously for a long time of period, enable LAMP RELAY.
• The brightness and color tint vary at the time of lamp switching.
82
R5905597 PHXX SERIES 28/01/2014