NEC 2400 IPX Whiteboard Accessories User Manual


 
NDA-24296 CHAPTER 2
Page 121
Revision 1.0
PH-SW10
Time Division Switch
Note:
When MUX card mode (SW03-4 ON), only MUX and CFT functions are valid. MUX 1 is used for a con-
nection to TSW (Dont use MUX 2, 3). The LED of MUXACT, M0SY, CFT, and PMCA are valid, other LED
is not lit. In this mode, only SW03 is valid.
SWITCH
NAME
SWITCH
NO
SETTING
STANDARD
SETTING
MEANING
SW03
1
ON 3-Party Conference Trunk (CFT) is valid.
OFF 3-Party Conference Trunk (CFT) is invalid.
2
ON Setting of A-law in the CFT function block.
OFF × Setting of µ-law in the CFT function block.
3OFF × Fixed.
4
ON
Only MUX function is valid (If this card is mounted in PIM
1/2/3). Note
OFF ×
TSW/INT/PLO/MUX are valid (When this card is mounted in
PIM 0).
SW04
1
ON DIU 0 is used as the DTI clock supply route zero.
OFF DIU 0 is not used.
2
ON DIU 1 is used as the DTI clock supply route one.
OFF DIU 1 is not used.
3
ON DIU 2 is used as the DTI clock supply route two.
OFF DIU 2 is not used.
4
ON DIU 3 is used as the DTI clock supply route three.
OFF DIU 3 is not used.
5
ON × 1.5 M clock for DIU 0
OFF 2 M clock for DIU 0
6
ON × 1.5 M clock for DIU 1
OFF 2 M clock for DIU 1
7
ON × 1.5 M clock for DIU 2
OFF 2 M clock for DIU 2
8
ON × 1.5 M clock for DIU 3
OFF 2 M clock for DIU 3