CHAPTER 3 NDA-24296
Page 560
Revision 1.0
PA-8TLTR
Tie Line Trunk
Note:
For the setting range of Programmable PAD Values, see the “Setting Range of Programmable PAD
Values” shown for SW1.
SWITCH
SWITCH
NO.
SETTING
STANDARD
SETTING
MEANING
SW3
(SW25)
1
ON Programmable PAD P2 Value 0.5 dB
P2 Values is total
of PAD Values
Note
(Valid when 4W
E&M system)
(Ex)
SW3-1: OFF
SW3-2: ON
SW3-3: OFF
SW3-4: OFF
in this case P2
value is 1 dB.
P3 Values is total
of PAD Values
Note
(Valid when 4W
E&M system)
(Ex)
SW3-5: OFF
SW3-6: ON
SW3-7: OFF
SW3-8: OFF
in this case P3
value is 1 dB.
OFF Programmable PAD P2 Value 0 dB
2
ON Programmable PAD P2 Value 1 dB
OFF Programmable PAD P2 Value 0 dB
3
ON Programmable PAD P2 Value 2 dB
OFF Programmable PAD P2 Value 0 dB
4
ON Programmable PAD P2 Value 4 dB
OFF Programmable PAD P2 Value 0 dB
5
ON Programmable PAD P3 Value 0.5 dB
OFF Programmable PAD P3 Value 0 dB
6
ON Programmable PAD P3 Value 1 dB
OFF Programmable PAD P3 Value 0 dB
7
ON Programmable PAD P3 Value 2 dB
OFF Programmable PAD P3 Value 0 dB
8
ON Programmable PAD P3 Value 4 dB
OFF Programmable PAD P3 Value 0 dB