NDA-24296 CHAPTER 2
Page 155
Revision 1.0
PZ-M565
Industry Standard Architecture Gateway
PZ-M565
Industry Standard Architecture Gateway
1. General Function
This circuit card has the relay functions as mentioned below:
(a) to receive the NMI (Non-Maskable Interruption) signal from the PZ-ME44 (PCI MEM) card, then
output it to ISA Bus.
(b) to receive the ACT signal from the EMA card, then output it to PZ-ME44 (PCI MEM) card.
This card is used in IPX-UMG system connecting the two cards on CPU#0 and #1 in CMP with a bus cable.
Figure 2-77 Location of PZ-M565 (ISAGT) Card in the System
2. Mounting Location/Condition
The PZ-M565 (ISAGT) card is mounted in PCI Slot No.05 on CPU Board within the CMP of IPX-UMG
system as shown in Figure 2-78.
Figure 2-78 External Interface for PZ-M565
CMP
EMA
MISC
DSPC
/MMC
PZ-M565
(ISAGT2)
PZ-GT13
(ISAGT)
LANI
LANI
CPU#0
PCI
MEM
ISA BUS
PZ-M565
(ISAGT2)
PZ-GT13
(ISAGT)
LANI
LANI
CPU#1
ISA BUS
PCI BUSPCI BUS
PCI
MEM
5.0
A
CMP-CPR
PCI bus ISA bus
PZ-PW92
DC-40V -58.6
I
O
SW
ON
OFF
ON
ALM
PALM
OUTPWR
INPWR
5A
125V
AC/DC
CPUOPE WDT IMG0
IMG1
IMG2
IMG3
PZ-M565