CHAPTER 3 NDA-24296
Page 586
Revision 1.0
PA-24PRTB-A
Primary Rate Interface Trunk
SWITCH
NAME
SWITCH
NO.
SETTING
STANDARD
SETTING
MEANING
SW1
1OFF
×
Standard setting (Digital PAD/ROM selection)
2ON
×
Fixed
3
ON Interface structure: 24B
OFF
×
Interface structure: 23B + D
4
ON D channel packet service is provided.
OFF
×
D channel packet service is not provided.
SW2
1
2
3
4ON
×
24-Multiframe
5ON
×
Zero Suppress Select B8ZS (24-multiframe)
6ON
×
Standard setting
7OFF
×
Standard setting
8
ON
×
Line fault is notified to the upper CPU.
OFF Line fault is not notified to the upper CPU.
SW3
1OFF
×
Fixed
2OFF
×
Fixed
3OFF
×
Alarm processing select Fixed to OFF
4OFF
×
Main Signal All 1 supervision is not made.
5ON
×
Fixed
6ON
×
Fixed
7ON
×
Fixed
8ON
×
Fixed
SETTING OF EQUALIOZER
SW2-1 SW2-2 SW2-3 DISTANCE
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
0 ~
40 ~
80 ~
120 ~
160 ~
40m
80m
120m
160m
200m
Other combinations Not allowed