NDA-24296 CHAPTER 3
Page 503
Revision 1.0
PA-4ILCH
ISDN Line Circuit
5. Switch Settings
Switches on this card have the following meanings.
SWITCH
NAME
SWITCH
NO.
SETTING
STANDARD
SETTING
MEANING
MB
UP Circuit card make busy
DOWN
×
Circuit card make busy cancel
MBR
0
ON Line 0 make busy request
OFF
×
Line 0 make busy request cancel
1
ON Line 1 make busy request
OFF
×
Line 1 make busy request cancel
2
ON Line 2 make busy request
OFF
×
Line 2 make busy request cancel
3
ON Line 3 make busy request
OFF
×
Line 3 make busy request cancel
LPB
0
ON Loop back is set on NT1 for line 0.
OFF
×
Loop back is canceled on NT1 for line 0.
1
ON Loop back is set on NT1 for line 1.
OFF
×
Loop back is canceled on NT1 for line 1.
2
ON Loop back is set on NT1 for line 2.
OFF
×
Loop back is canceled on NT1 for line 2.
3
ON Loop back is set on NT1 for line 3.
OFF
×
Loop back is canceled on NT1 for line 3.
MODE
0-2 Not used
3
×
Fixed
4-F Not used
SW10
1ON
×
Fixed
2
ON
×
D-channel Packet Service Available
OFF D-channel Packet Service Not Available
3ON
×
Fixed
4ON
×
Fixed