NDA-24296 CHAPTER 3
Page 583
Revision 1.0
PA-24PRTB-A
Primary Rate Interface Trunk
2. Mounting Location / Condition
The PA-24PRTB-A (24PRT) card can be mounted in the following shaded universal slots as shown below.
Note:
This card cannot be mounted in slot 5.
This card cannot use Group0 (G=00) of Unit0 (U=0) of even-number Module Group.
3. Face Layout of Lamps, Switches, and Connectors
The face layout of lamps, switches, and connectors of this circuit card is shown in Figure 3-182.
Figure 3-182 Face Layout of PA-24PRTB-A (24PRT)
PIM
Mounting Module
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Universal Slots
Universal Slots
Note
OPE
N-OPE
MB
BL23
BL00
MODE
CN2
2
3
0
1
LB
PCM
BER
AIS
FRM
RMT
DOPE
PKT
LYR
SW0
SW2 SW3 SW4 SW5
SW1