280 Technical data
Electrical
Electrical specifications
210 to 246 VAC
Voltage
Scanner 120 VAC
Printer Single phase 214 to 250 VAC
Three phase 185 to 215 VAC
Current (Amps)
Scanner 20 A
Printer 30 A
Power consumption (Watts) Scanner Printer
Running 1100 5800
Standby 1000 5100
Environmental data
Operating range
Relative humidity 15% to 85%
Temperature 50
0
F to 90
0
F
Heat output
Running 11,068 BTU/hr.
Standby 2700 BTU/hr.
Audible noise (scanner and printer)
Running 49.5 db (A) or less
Standby 64 db (A) continuous
72 db (A) maximum
Ozone
Concentration based on simulation model:
Daily copy volume: 8250 copies/8 hours
Room size: 17 m
3
0 Air changes per hour
77.6 ug/min
0.009 ppm (time weighted average)
0.016 ppm (peak) threshold limit value (0.10
ppm)
Total dust
0.04 mg/m
3
threshold limit value (10
mg/m
3
)
Organics
<10ppb