Zebra Technologies 3ULQWHUV Printer User Manual


 
Appendixes
Specifications and Care
Zebra XiIIIPlus Users Guide 119
2. Remove the faulty fuse and install a new fuse in the in-circuit position as shown. If
you use the spare fuse, be sure to order a replacement fuse from your Zebra
distributor.
The illustration callouts and the table that follows identify the parts of the fuse
holder.
3. Snap the fuse holder back into the AC power entry module.
4. Reconnect the power cord and turn the printer On (I).
AC power entry module
Small-blade screwdriver
&DOORXW 'HVFULSWLRQ
Fuse holder
In-circuit fuse
Spare fuse
Caution • The spare fuse should be the exact type and rating as the original in-
circuit fuse.
Note • If the AC power is not restored, an internal component failure may have
occurred and the printer requires servicing by an authorized service technician.
&DOORXW 'HVFULSWLRQ
2
3
1