Zebra Technologies 3ULQWHUV Printer User Manual


 
20 Zebra XiIIIPlus Users Guide
Printer Setup and Calibration
Before You Begin
No, a label did not print. Sensors out of position is a common cause of printing
problems.
6HQVRU$GMXVWPHQW
Adjust sensors only when the printer cannot detect the top of the label. The front panel
LCD displays (5525&21',7,213$3(5287, even though there are labels loaded in
the printer.
7UDQVPLVVLYH6HQVRU
The transmissive sensor consists of two sections: a light source (the lower media
sensor) and a light sensor (the upper media sensor). The media passes between the two.
The upper media sensor must be positioned:
Directly over the hole or notch, or
Anywhere along the width of the media if there is a gap between labels.