Data Ports
Standard Ports
Zebra XiIIIPlus Users Guide 43
'%WR'%FRQQHFWLRQV
An interface adapter is required (Zebra part number 33138) to connect the printer’s
DB-9 interface to a DB-25 connector. A generic DB-25 adapter may also be used. The
+5 VDC signal source would not be passed through a generic adapter.
This illustration shows the connections required for the DB-9 to DB-25 interface.
Male DB-9 Adapter
Connector
(plugs into printer)
Female DB-25 Adapter
Connector
(plugs into cable)
NOTE: Pin 1 of DB-9 connector is unused and unterminated.
FG
TXD
RXD
RTS
DSR
SG
DTR
RXD
TXD
DTR
SG
DSR
RTS
CTS
+5 VDC
SIGNAL
2
3
4
5
6
7
8
9
1
2
3
4
6
7
9
20
+5 VDC
SIGNAL
5
CTS