292 CHAPTER 5: SYSTEM CONFIGURATION
Verifying a Failed
Disk Drive
If either disk fails while in a fully mirrored state, the system continues to
operate. The disk LED states described in Table 59
indicate which drive
has failed. In addition, the Disk Status window in NBX NetSet shows the
status of your disk drives.
To verify the status of a disk drive, select Reports > System Data > Disk
Status. See the Help for information on verifying disk status.
Boot process completed, system initializing Flashing N/A N/A On
System is running On N/A N/A On
Flash codes indicate disk problem:
2 flashes: No valid disk (system is halted)
3 flashes: Two valid disks, but they are not
paired (system is halted)
4 flashes: Configuration problem (system is
halted)
5 flashes: Two disks present, but no
mirroring license
N/A Flashing Flashing On
Using disk 0 (zero) only N/A On Off On
Using disk 1 only N/A Off On On
Synchronizing — disk 0 is valid, disk 1 is
becoming a fully mirrored disk. LED 3 flash rate
indicates progress.
If LED 3 stops normal flashing and intermittently
flashes twice, the mirroring process has failed.
N/A On Flashing On
Synchronizing — disk 1 is valid, disk 0 is
becoming a fully mirrored disk. LED 2 flash rate
indicates progress.
If LED 2 stops normal flashing and intermittently
flashes twice, the mirroring process has failed.
N/A Flashing On On
LED 2 and LED 3 flash alternately: the two disks
are resynchronizing
N/A Flashing Flashing On
Synchronized N/A On On On
Table 59 Disk LED States (continued)
Explanation LED 1 LED 2 LED 3 PWR