Cisco Systems ONS 15310-MA Switch User Manual


 
2-31
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter 2 Alarm Troubleshooting
2.7.31 AUTOSW-UNEQ (STSMON)
2.7.31 AUTOSW-UNEQ (STSMON)
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: STSMON
The Automatic Path Protection Switch Caused by Unequipped condition indicates that an UNEQ alarm
caused automatic path protection switching to occur (see the “UNEQ-P” condition on page 2-142). If the
path protection is configured for revertive switching, it reverts to the working path after the fault clears.
Note This condition is only reported if the path protection is set up for revertive switching.
Clear the AUTOSW-UNEQ (STSMON) Condition
Step 1 Complete the “Clear the UNEQ-P Alarm” procedure on page 2-142.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.32 AUTOSW-UNEQ (VT-MON)
Default Severity: Minor (MN), Service-Affecting (SA)
SONET Logical Object: VT-MON
The automatic path protection switch caused by an unequipped condition (VT-MON) indicates that the
“UNEQ-V” alarm on page 2-144 alarm caused automatic path protection switching to occur. If the path
protection is configured for revertive switching, it reverts to the working path after the fault clears.
Note This condition is only reported if the path protection is set up for revertive switching.
Clear the AUTOSW-UNEQ (VT-MON) Alarm
Step 1 Complete the “Clear the UNEQ-V Alarm” procedure on page 2-144.
Step 2 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447) in order to report a Service-Affecting (SA)
problem.
2.7.33 BAT-FAIL
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: PWR