1.7 Restore the Database and Default Settings
Step 5 Clear the terminal loopback on the port:
a. Double-click the source-node CE100T-8 card with the terminal loopback.
b. Click the Maintenance > Loopback tabs.
c. Select None from the Loopback Type column for the port being tested.
d. Select the appropriate state (IS; OOS,DSBLD; OOS,MT) in the Admin State column for the port
being tested.
e. Click Apply.
f. Click Yes in the confirmation dialog box.
Step 6 Clear the terminal loopback circuit:
a. Click the Circuits tab.
b. Choose the loopback circuit being tested.
c. Click Delete.
d. Click Yes in the Delete Circuits dialog box. Do not check any check boxes.
The entire circuit path has now passed its comprehensive series of loopback tests. This circuit qualifies
to carry live traffic.
1.7 Restore the Database and Default Settings
This section contains troubleshooting procedures for errors that require restoration of software data or
the default node setup.
1.7.1 Restore the Node Database
Symptom One or more nodes are not functioning properly or have incorrect data.
Table 1-1 describes the potential cause of the symptom and the solution.
1.8 PC Connectivity Troubleshooting
This section contains information about system minimum requirements, supported platforms, browsers,
and Java Runtime environments (JREs) for Software Release 7.0, and troubleshooting procedures for
Windows PC and network connectivity to the ONS 15310-CL or ONS 15310-MA.
Table 1-1 Restore the Node Database
Possible Problem Solution
Incorrect or corrupted
node database.
Complete the applicable procedures in the “Maintain the Node” chapter of
the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.