Cisco Systems ONS 15310-MA Switch User Manual


 
3-7
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter 3 Transient Conditions
3.3.20 LOGOUT-IDLE-USER
This transient condition is equivalent to a security warning. You must check the security log (audit log)
for other security-related actions that have occurred.
3.3.20 LOGOUT-IDLE-USER
The Automatic Logout of Idle User (LOGOUT-IDLE-USER) condition occurs when a user session is
idle for too long (the idle timeout expires) and the session terminates as a result. You must log in again
to restart your session.
3.3.21 MANWKSWBK-NO-TRFSW
The Manual Switch Back To Working Resulted in No Traffic Switch (MANWKSWBK-NO-TRFSW)
condition occurs when you perform a Manual switch to the working port/card and the working port/ card
is already active.
This transient condition does not result in a standing condition.
3.3.22 MANWKSWPR-NO-TRFSW
The Manual Switch to Protect Resulted in No Traffic Switch (MANWKSWPR-NO-TRFSW) condition
occurs when you perform a Manual switch to the protect port/card and the protect port/card is already
active.
This transient condition does not result in a standing condition.
3.3.23 PM-TCA
The Performance Monitor Threshold Crossing Alert (PM-TCA) condition occurs when network
collisions cross the rising threshold for the first time.
3.3.24 PS
The Protection Switch (PS) condition occurs when the traffic switches from a working/active card to a
protect/standby card.
3.3.25 PSWD-CHG-REQUIRED
The User Password Change Required (PSWD-CHG-REQUIRED) condition occurs when you are denied
login for a shell function such as Telnet or FTP because you did not change the login password. You can
change the password through CTC or TL1.
3.3.26 RMON-ALARM
The Remote Monitoring Threshold Crossing Alarm (RMON-ALARM) condition occurs when the
remote monitoring (RMON) variable crosses the threshold.