Cisco Systems ONS 15310-MA Switch User Manual


 
4-33
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter 4 Error Messages
EID-5018 {0} is {1} node and cannot be added to {2} network. You cannot add the node {0} of type {1} to
the host node of type {2}. This prevents you
from hosting both SONET and SDH nodes
in the same session.
EID-5019 Manual mode for this equipment does not support an expected
string consisting of all null characters. Please change the
expected string or the path trace mode.
The path trace mode does not support
strings that consist of null characters. You
must either change the expected string or
the path trace mode.
WID-5020 Unable to transition port state indirectly because the port
aggregates low order circuits: if the port state should be
changed, edit it directly via port provisioning
Refer to the warning message text.
EID-5021 No nodes are selected. Please choose a node. Refer to the error message text.
WID-5022 Warning: Ethergroup circuits are stateless (i.e., always in
service).
Current state selection of {0} will be ignored.
Refer to the warning message text.
EID-5023 Unable to communicate with node.
Operation failed.
CTC encountered a network
communication error. Connectivity between
CTC and the NE was disrupted, either
transiently or permanently.
EID-5024 Overhead circuit will not be upgraded. Refer to the error message text.
WID-5025 The path targeted for this switch request is already active. The
switch request can be applied, but traffic will not switch at this
time.
Refer to the warning message text.
EID-5026 A 15600 cannot serve as the primary or secondary node in a 4
Fiber {0} circuit. Please change your ring and/or node
selections so that a 15600 is not chosen as the primary or
secondary node in this 4 Fiber {1} circuit.
Refer to the error message text.
WID-5027 The {0} Edit Window for {1} has been closed due to significant
provisioning changes. These changes may only be transitory, so
you may re-open the {0} Edit Window to view the updated
state.
Re-open the BLSR/MS-SPRing edit
window to view the updated state of the
ring.
WID-5028 Warning: This operation should only be used to clean up rolls
that are stuck. It may also affect completeness of the circuit.
Continue with deletion?
Refer to the warning message text.
EID-5029 A software downgrade cannot be performed to the selected
version while an SSXC card is inserted in this shelf. Please
follow the steps to replace the SSXC with a CXC card before
continuing the software downgrade.
Refer to the error message text.
EID-5030 A software downgrade cannot be performed at the present time. Try the software downgrade later.
WID-5031 Cancelling a software upgrade during standby TSC clock
acquisition may result in a traffic outage.
Refer to the warning message text.
EID-5032 Error accepting load. Refer to the error message text.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description