Chapter 4 Error Messages
EID-3021 An error was encountered while retrieving the diagnostics:
{0}
Refer to the error message text.
EID-3022 Requested action not allowed. The requested action is not allowed.
EID-3023 Unable to retrieve low order cross connect mode. Refer to the error message text.
EID-3024 Unable to switch {0} cross connect mode.
Please verify that the type and/or number of circuits
provisioned does not exceed the criterion for switching modes.
CTC cannot switch the cross-connect mode
for the specified item, as the type or the
number of circuits does not match with the
criterion for switching modes.
EID-3025 Error while retrieving thresholds. There was an error retrieving the thresholds.
EID-3026 Cannot modify send DoNotUse. You cannot modify the Send DoNotUse
field.
EID-3027 Cannot modify SyncMsg. You cannot modify the SyncMsg field.
EID-3028 Cannot change port type. You cannot change the port type.
EID-3029 Unable to switch to the byte because an overhead change is
present on this byte of the port.
Refer to the error message text.
EID-3031 Error hard-resetting card. There was an error while resetting card
hardware.
EID-3032 Error resetting card. There was an error while resetting the card.
EID-3033 The lamp test is not supported on this shelf. Refer to the error message text.
EID-3035 The cross connect diagnostics cannot be performed Refer to the error message text.
EID-3036 The cross connect diagnostics test is not supported on this shelf. The cross-connect diagnostics test is not
supported on this shelf.
EID-3039 Card change error. There was an error while changing the card.
EID-3040 Invalid card type. The selected card type is invalid.
EID-3041 Error applying changes. CTC is unable to create a protection group.
Check if the protect port supports circuits, a
timing reference, SONET SDCC,
orderwire, or a test access point.
EID-3042 The flow control low value must be less than the flow control
high value for all ports in the card.
Refer to the error message text.
EID-3046 The flow control water mark value must be between {0} and
{1}, inclusive.
The flow control watermark value must be
between the two specified values.
EID-3047 The file named {0} could not be read. Please check the name
and try again.
Refer to the error message text.
EID-3048 There is no IOS startup config file available to download. CTC could not find the configuration file
for IOS startup.
EID-3049 There is an update in progress so the download cannot be done
at this time.
Refer to the error message text.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description